Experts in coffee? The RObust coffee unit is made for you: Up to 75L/h of purified water, a mineral balance that meets the Speciality Coffee Association standards and a snug design to fit neatly under counters - it's built for the coffee connoisseurs.

Expect optimised water quality and consistent flavours in every drink with this system.


Technical Information

Parameters
Parameter Specification
Flow capacity 70-75 L/h
Water consumption 140–150 L/h
Waste water 70-75 L/h
Inlet water pressure 2-5 bar
Electrical requirement 100-240 V, 50-60 Hz
Power consumption 0,08 kW
System Components
  • Assembled filter
  • Pre–filters and post–filter
  • Reverse osmosis membrane
  • Drain saddle
  • Installation fitting set
  • Purified water faucet
  • Set of tubes
  • Service wrench
Source water requirements
Parameter Specification
pH 6.5–8.5
Total dissolved solids (TDS) <150–500 ppm
Hardness <100–400 ppm CaCO₃
Chlorine ≤0.5 ppm
Iron ≤0.3 ppm
Manganese ≤0.05 ppm
Chemical oxygen demand
≤5 ppm O₂
Total microbial count ≤100 CFU/mL
Coliform index None
Service & maintenance

The RObust COFFEE direct flow reverse osmosis filter is designed for cold water purification only.

Pressure monitoring

The front panel features two pressure gauges:

  • Inlet pressure gauge – shows pressure after the pre-filters.
  • Pump pressure gauge – shows pressure after the membrane block.
1 This value only applies to the RObust 1500, RObust 3000MAX, and RObust 4000 models.


Pre-filtration cartridges


Replace pre-filters after 3,000 litres of water filtration or at least every 3 months.
If the pressure after the pre-filters drops below 1 bar, the cartridges may be clogged.
Delaying replacement may damage or reduce the lifespan of the membrane.


Reverse osmosis membrane


With a significant drop in system performance, replacement of reverse osmosis membranes is required. Replace after filtering 30,000 liters or at least once per year if filtration speed decreases.


Post-filtration cartridge

Replace if taste deteriorates or odour appears, after 5,000 litres or at least every 3 months. Important: Replace all cartridges together as a set.


Downtime maintenance

If unused for over 2 weeks, disinfect before resuming use (procedure in the user manual).

  • Compatible replacement solutions

RObust COFFEE Set of 4 Replacement Filters

Ecosoft 500 GPD membrane element

RObust connection kit for Ecosoft RObust filters

FAQ

Do your filtration products achieve SCA-compliant water for coffee making?

Yes, you can achieve SCA-compliant water with our products.

Our direct flow reverse osmosis system, RObust COFFEE, was specifically designed for coffee preparation and delivers water that meets SCA standards.

Which TDS do I need for the perfect brew and can I achieve it with Ecosoft?

Yes, Ecosoft water treatment systems can help you reach the TDS levels recommended by the SCA.

The SCA suggests a TDS range of 75–250 ppm, but it’s important to remember that the composition of total dissolved solids plays a major role in how your coffee tastes. With an optimal balance of calcium (Ca) and magnesium (Mg), the RObust COFFEE creates water that enhances the unique aromas and flavors of each coffee bean.
Do I need to use a tank with your water purification systems in my café?

While it’s not strictly necessary to use a tank with our water filtration systems, we do recommend it.

Using a tank helps stabilise TDS levels in the water, which results in more consistent coffee flavour.
What TDS levels can I achieve in my café with your water purification systems?

The exact TDS levels vary by product:

RObust COFFEE achieves TDS levels of 60–120 ppm
RObust Mini, RObust 1500 and similar models achieve 10–30 ppm
Some of our systems, like the RObust COFFEE, allow you to adjust the TDS level using flow restrictors. These restrictors are included in your café kit, and instructions can be found inside the box or under Downloads on this page (left sidebar).
What TDS is required for the inlet water?
The required TDS level of the inlet water depends on the filter model.
All our RObust reverse osmosis filters require a TDS level of 1,000 ppm or less except for RObust Coffee. For this one the required TDS is 150-500 ppm.